Cleaning Instructions

CLEANING INSTRUCTIONS FOR THE SMALL AND MEDIUM MASK CHAMBERS. THIS PRODUCT CAN BE USED RIGHT OUT OF THE PACKAGE AND THEN CLEANED WEEKLY.

 


Remove the backpiece. To detach from the frontpiece, twist chamber as shown.

 


Soak the parts for 15 minutes in a mild solution of liquid dish detergent and lukewarm clean water. Agitate gently.

Rinse parts in clean water.


OR

 

Dishwasher safe under the following conditions:

  • Avoid heavy or other cycles that include heated dry over 158°F
  • Parts must be placed in the top rack ONLY 
  • Secure product face up, as pictured
  • Use dishwasher detergent and rinse aid
  • Do not boil or sterilize

SEE CAUTION #1 BELOW

 

 


Shake out excess water from the parts and allow to air dry in a vertical position. Ensure parts are dry before reassembly.

 


To reassemble, fit the frontpiece on the end of the chamber and twist firmly until securely locked into position.

 


Center the Alignment Feature on the backpiece with the Flow-Vu® Inspiratory Flow Indicator, as shown. Press firmly to attach the backpiece.

CLEANING INSTRUCTIONS FOR THE LARGE MASK AND MOUTHPIECE CHAMBERS. THIS PRODUCT CAN BE USED RIGHT OUT OF THE PACKAGE AND THEN CLEANED WEEKLY.

 


Remove the backpiece. To detach from the frontpiece, twist chamber as shown.
Remove the mouthpiece cap.

 


Soak the parts for 15 minutes in a mild solution of liquid dish detergent and lukewarm clean water. Agitate gently.

Rinse parts in clean water.


OR

 

Dishwasher safe under the following conditions:

  • Avoid heavy or other cycles that include heated dry over 158°F
  • Parts must be placed in the top rack ONLY 
  • Secure product face up, as pictured
  • Use dishwasher detergent and rinse aid
  • Do not boil or sterilize

SEE CAUTION #1 BELOW

 

 


Shake out excess water from the parts and allow to air dry in a vertical position. Ensure parts are dry before reassembly.

 


To reassemble, fit the frontpiece on the end of the chamber and twist firmly until securely locked into position.

For mouthpiece models, the protective cap should always be placed on the mouthpiece when the chamber is not in use.

 


Center the Alignment Feature on the backpiece with the Flow-Vu® Inspiratory Flow Indicator, as shown. Press firmly to attach the backpiece.

Full Instructions for Use 

Notes:

  • Storage and operating range is 5°C – 40°C (41°F – 104°F) at 15 to 95% relative humidity.
  • Product may need to be replaced after 12 months of use. Environmental conditions, storage and proper cleaning can affect product life span.
  • Do not share this medical device.
  • If you notice medication build-up in your chamber, wash the inside of the chamber gently with a soft cloth.
  • Dishwashing with overly dirty dishes is not recommended.
  • Dishwasher validated up to 158°F (70°C).
 
INDICATIONS FOR USE AND CAUTIONS

This product is intended to be used by patients who are under the care or treatment of a physician or licensed healthcare professional. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers. The intended environments for use include the home, hospitals and clinics.

CAUTIONS:
  • PRODUCT MAY BE PERMANENTLY DAMAGED IF BOILED, STERILIZED,
    OR CLEANED IN A DISHWASHER AT TEMPERATURES ABOVE 158°F (70°C).
  • Do not leave the chamber unattended with children.
  • Federal (USA) law restricts the sale of this device on or by the order of a physician.

Please see Instructions for Use for additional information.

Available by prescription only.